Teko_ModALPreconditioner_MPI_1 Failing in build Trilinos-atdm-cee-rhel6-clang-5.0.1-openmpi-1.10.2-serial-static-opt
Created by: fryeguy52
CC: @trilinos/teko , @srajama1 (Trilinos Linear Solvers Product Lead), @bartlettroscoe
Next Action Status
With the merge of PR #4079 to 'develop' on 12/19/2018, this test Teko_ModALPreconditioner_MPI_1
is disabled and shown missing in the build Trilinos-atdm-cee-rhel6-clang-5.0.1-openmpi-1.10.2-serial-static-opt
on 12/20/2018.
Description
As shown in this query the tests:
- Teko_ModALPreconditioner_MPI_1
are failing in the builds:
- Trilinos-atdm-cee-rhel6-clang-opt-serial
failing from a seg fault:
[ceerws1113:36105] *** Process received signal ***
[ceerws1113:36105] Signal: Segmentation fault (11)
[ceerws1113:36105] Signal code: Address not mapped (1)
[ceerws1113:36105] Failing at address: (nil)
Steps to Reproduce
One should be able to reproduce this failure any CEE LAN RHEL6 SRN machine as described in:
More specifically, the commands given for the CEE LAN RHEL6 SRN machines are provided at:
The exact commands to reproduce this issue should be:
$ cd <some_build_dir>/
$ source $TRILINOS_DIR/cmake/std/atdm/load-env.sh cee-rhel6-clang-opt-serial
$ cmake \
-GNinja \
-DTrilinos_CONFIGURE_OPTIONS_FILE:STRING=cmake/std/atdm/ATDMDevEnv.cmake \
-DTrilinos_ENABLE_TESTS=ON -DTrilinos_ENABLE_Teko=ON \
$TRILINOS_DIR
$ make NP=16
$ ctest -j16